Sunday, August 7, 2011

How Energy Recovery Ventilators Work:

How Energy Recovery Ventilators Work:
In the RenewAire (formerly Lossnay) energy exchange core, the exhausted stale air and the fresh ventilation air pass through multiple air passages separated by an engineered composite resin partition plate. Sensible heat transfers from the warmer to the cooler air stream. Also, latent energy (water vapor in the gas state) transfers from the wetter to the drier air stream. The fresh incoming air is automatically preheated or precooled depending on the season. This dramatically reduces the energy costs of ventilation.
This unique moisture transfer feature of the RenewAire (formerly Lossnay) energy exchange core eliminates condensate and frosting in most applications. No mechanical or electrical defrost systems are needed, which means higher heat recovery efficiencies, simpler installation and more reliable operation.

During the Heating Season:
Outdoor air is warmed to close-to-room temperature with heat that would otherwise be lost with the exhaust air. Indoor humidity levels are prevented from becoming too dry or too humid by the partial transfer of water vapor. Non-enthalpic heat recovery systems cannot deliver that benefit.


During the Air Conditioning Season:
RenewAire (formerly Lossnay) Core systems recover coolness and dryness from the exhausted air. Outside air brought in for ventilation is reduced in temperature and humidity because its heat and humidity is transferred to the exhaust air stream.
With summer-time humidity (latent load) being the largest portion of the cooling load associated with outside air ventilation, this humidity transfer is critical. Other plate-type heat exchangers can’t touch this major load. RenewAire (formerly Lossnay) makes it easier for your air conditioning system to keep you both cool and dry.



INSTALLATIONS, SIZES, AND SAVINGS - Click Here
Energy Recovery Ventilators
Typical
Sizing Calculator
Economy


Here is a Typical AirMulti Energy Recovery Ventilator Installation:
The installations below are examples of a residential and a commercial application




Why AirMulti Energy Recovery Ventilators
Are Your Best Indoor Air Quality Solution
Winter: Humidity level control without over drying.

Passive freeze protection design (dehumidified exhaust air stream depresses dew point temperature below actual temperature).

No condensate pan or drain for easier installation and no associated biological growths.


Summer: Reduced cooling load on the air conditioning equipment.
• Moderates humidity extremes associated with outside air ventilation.


Year
Round: Reliable fixed plate design versus heat wheel, heat pipe, metallic or plastic fixed plate alternatives.
• Low maintenance, no moving parts
• expandable designs for unlimited CFM
• 10 year energy exchange core warranty
• Proven in all climates
• Simple and easy to control

WHAT SIZE RENEWAIRE UNIT IS RIGHT FOR YOUR HOME?

If your air requirements are greater than 210 CFM, give us a call at 435-722-5877 or drop us an e-mail and we will design your system.
50 - 130 CFM EV- 130

100 - 200 CFM EV- 200


RenewAire (formerly Lossnay) ENERGY RECOVERY VENTILATORS ARE available in a wide range of sizes and configurations to suit virtually any application form residential to applied-commercial to institutional. Since its introduction in 1970, the RenewAire (formerly Lossnay) Core has provided energy-efficient ventilation in thousands of systems throughout North America and around the globe. In fact, more RenewAire (formerly Lossnay) Cores have been used in energy recovery ventilation systems than any other core in the world.

RenewAire (formerly Lossnay) ERVs SAVE UP TO seventy-five percent in energy costs
The RenewAire (formerly Lossnay) energy recovery system saves money by reducing the workload on your heating and cooling equipment when bringing in fresh air. The equipment can then be smaller than you would have to buy if you were using other types of ventilation equipment. In fact, you’ll save up to 75% in energy compared to typical ventilation systems, resulting in lower utility bills in both the heat of summer and the cold of winter.
RESIDENTIAL VENTILATION EXAMPLE (130 CFM)
Balanced Ventilator
(No energy recovered) RenewAire EV130
(75% energy recovered)
HEAT LOAD AT 10 F (indoor 70 F, 35% RH) 11,800 BTU/hour 4,100 BTU/hour
AC LOAD AT 95 F, 75 F WB (indoor 75 F, 50% RH) 6,100 8TU/hour 3,366 8TU/hour
TYPICAL FURNACE SIZE 60,000 BTU/hour 45,000 BTU/hour
TYPICAL AIR CONDITIONER SIZE 3 tons 2.5 tons
ANNUAL HEATING FUEL SAVINGS FOR NATURAL GAS
ANNUAL HEATING FUEL SAVINGS FOR ELECTRICITY $100/YR- LESS THAN 5-YEAR PAYBACK*
$295/YR- LESS THAN 2-YEAR PAYBACK*
* Example based on net additional cost for energy recovery.
Call us for an evaluation of possible savings in your area.

FLEXIBILITY: stand-alone or heating system installation.
RenewAire (formerly Lossnay) Energy Recovery Ventilators (ERV) can be installed as a stand-alone unit or connected to your heating system.

No comments: